Inner wire | Galvanized steel | Lining | Polypropylene |
---|---|---|---|
Outer cover | Polyester PVC coated BLUE | Out wire | Galvanized steel |
Maximum elongation | 10% on proof pressure | Max flowrate | on request |
---|---|---|---|
Electrical resistance | ≤ 2.5 Ohm/m for sizes less than 50mm ≤ 1.0 Ohm/m for the 50mm size and above sizes |
Max tensile strength | on request |
Maximum twist | 10˚p/m | Pressure losses | on request |
Vacuum range | 0.9 bar | Temperature range | -30°C up to +80°C |
Min. burst pressure | 5 x working pressure (safety fact 5:1) |
Bore Diameter / Max. Working Pressure / Bend Radius / Weight | |||||||
---|---|---|---|---|---|---|---|
INS | MM | BARS | PSI | INS | MM | KG/M | LB/FT |
1 | 25 | 14 | 200 | 4.0 | 100 | 0.8 | 0.5 |
1.5 | 38 | 14 | 200 | 5.5 | 140 | 1.2 | 0.8 |
2 | 50 | 14 | 200 | 7.0 | 180 | 1.9 | 1.3 |
2.5 | 65 | 14 | 200 | 8.0 | 205 | 2.5 | 1.7 |
3 | 75 | 14 | 200 | 11 | 280 | 3.0 | 2.0 |
Heavy Duty | |||||||
---|---|---|---|---|---|---|---|
INS | MM | BARS | PSI | INS | MM | KG/M | LB/FT |
4 | 100 | 14 | 200 | 16.0 | 405 | 6.4 | 4.3 |
6 | 150 | 14 | 200 | 20.0 | 510 | 10.7 | 7.2 |
8 | 200 | 14 | 200 | 30.0 | 760 | 15 | 10.0 |
10 | 250 | 10.5 | 150 | 36.0 | 915 | 20.5 | 13.7 |